How do I set up a planned maintenance schedule for a hotel?

· Last updated

List every asset, then schedule the statutory checks first: fire alarm, emergency lighting, Legionella, gas, lifts and electrical. Add manufacturer tasks, group everything as daily, weekly, monthly, seasonal or annual, give each task one owner, and record every completion with a date and a photo.

What are the steps to build a hotel maintenance schedule?

A schedule is a list of repeating jobs, each with a frequency and an owner. Build it in this order, so the safety checks are in place before the comfort tasks.

  • List the assets: boilers, water heaters and tanks, fire alarm panel, emergency lights, lifts, kitchen equipment, air conditioning, and the guest rooms by floor.
  • Set the statutory checks first, each with its frequency and the rule behind it (the table below).
  • Add the manufacturer tasks: service intervals and filter changes from each asset's manual or warranty.
  • Add SFG20-aligned tasks for assets where you want a published task list to work from.
  • Group every task by how often it comes round: daily, weekly, monthly, seasonal or annual.
  • Give each task one owner, in-house or a named contractor, and keep a record each time it is done.

Which statutory checks go on a hotel schedule, and how often?

Most of these intervals come from codes of practice and HSE guidance, not from the law itself. The law sets the duty to keep the equipment safe, and the code tells you what counts as doing that. The table was checked on 18 November 2026.

Hotel statutory maintenance checks: how often, and the instrument behind each
CheckHow oftenWhere it comes from
Fire alarmTest one call point every week, using a different one each time. A competent person services the system at intervals of no more than six months.BS 5839-1 sets the intervals. The legal duty is article 17 of the Regulatory Reform (Fire Safety) Order 2005 (RRO 2005): keep fire safety measures in efficient working order.
Emergency lightingA short function test every month and a full-duration test once a year, usually three hours.BS 5266-1 sets the intervals. The legal duty is again article 17 of the RRO 2005.
Legionella and water hygieneTemperature checks at sentinel outlets every month, and flushing of any outlet not used at least weekly.HSE Approved Code of Practice L8 and guidance HSG274 set the regime under the Health and Safety at Work etc. Act 1974.
Portable electrical equipment (PAT)No fixed legal interval. Set it by risk: a guest-room kettle and a daily-use vacuum cleaner need different frequencies.The IET Code of Practice for in-service inspection. The Electricity at Work Regulations 1989, regulation 4, requires equipment to be maintained to prevent danger.
Gas appliances, pipework and fluesNo interval is written into the regulation. An annual service by a Gas Safe registered engineer is the accepted practice, or the manufacturer's interval where it differs.Gas Safety (Installation and Use) Regulations 1998, regulation 35: keep them maintained in a safe condition. HSE guidance for employers.
Passenger liftsA thorough examination at least every six months, or to an examination scheme drawn up by a competent person.Lifting Operations and Lifting Equipment Regulations 1998 (LOLER), regulation 9.

What else belongs on the schedule beyond the statutory checks?

Take manufacturer tasks from each asset's manual: boiler services, air-conditioning filters, kitchen extraction cleaning, hot water cylinder checks. Doing them keeps the warranty valid and the plant running through a full house.

SFG20 is the industry library of maintenance task lists, sold by BESA. It is not a law. Use it as a starting task list for an asset if you hold a licence. Fixray's SFG20 alignment is in progress, and Fixray does not resell SFG20 schedules.

How should you group tasks by daily, weekly, monthly, seasonal and annual?

Group by how often a task comes round, because each group has a different owner and rhythm.

  • Daily: walk-rounds of public areas, and kitchen and plant-room checks the head chef or duty engineer signs off.
  • Weekly: fire alarm call point test, flushing of rooms and outlets that stood empty, and a sample of guest-room checks.
  • Monthly: emergency lighting function test, Legionella temperature checks, and boiler and pump visual checks.
  • Seasonal: heating start-up in autumn, air-conditioning in spring, gutters and external lighting before winter.
  • Annual: the full-duration emergency lighting test, gas appliance services, and a review of the fire risk assessment.

Who owns each task, and what record do you keep?

Name one person for each task, even when a contractor does the work: the owner is the one who chases it. Record each completion with who did it, the date, and a photo where it helps, so the trail exists the day an inspector, insurer or buyer asks.

A recurring check that is held in someone's memory stops the week that person is off. A schedule with owners and a record keeps going when staff change.

Where does Fixray fit?

Fixray is the execution and evidence layer for the schedule. Each recurring check becomes a repeating job with an owner and a due date, staff close it from the Fixray app with a photo, and every completion is saved with who did it and when. Fixray does not tell you what your duties are and does not make a hotel compliant.

Free includes one active scheduled job. Planned maintenance across every asset comes with Plus, and Pro includes it too. Staff get the Fixray app from the App Store or Google Play. Guests scan a QR code and report with no app and no account.

Sources

Frequently asked questions

What should a hotel planned maintenance schedule include?
A list of assets, the statutory checks with their frequencies, the manufacturer service tasks, a frequency for each (daily, weekly, monthly, seasonal or annual), one owner per task, and a record of each completion.
How often should a hotel test its fire alarm?
BS 5839-1 recommends testing one call point every week, using a different one each time, with a service by a competent person at intervals of no more than six months. The legal duty is article 17 of the Regulatory Reform (Fire Safety) Order 2005, which requires fire safety measures to be kept in efficient working order.
Is PAT testing a legal requirement for hotels?
No law fixes an interval for PAT testing. The Electricity at Work Regulations 1989 require equipment to be maintained to prevent danger, and the IET Code of Practice sets intervals by risk.
How often must a hotel lift be inspected?
A passenger lift needs a thorough examination at least every six months under regulation 9 of LOLER 1998, or to an examination scheme drawn up by a competent person.
Does a hotel need a gas safety check every year?
Regulation 35 of the Gas Safety (Installation and Use) Regulations 1998 requires gas appliances, pipework and flues at a workplace to be kept in a safe condition, and sets no interval. An annual service by a Gas Safe registered engineer is the accepted practice, unless the manufacturer says otherwise.
Can Fixray make my hotel compliant?
No. Compliance rests with your responsible person and the competent people who carry out the work. Fixray is where each check is scheduled, assigned, completed and recorded.

Try the free tier on one site

Fixray's Free tier is free forever for one site, with unlimited Reporters and 20 new issues a month. No credit card, no sales call.